Smart Cultivator Controller Software Release Notes
5.5.2 – Released October 30, 2024
Fixes:
- Lane ID numbering in alarm messages now matches camera IDs
5.5.1 – Released October 25, 2024
New features:
- Optional lockout to prevent starting the machine if a job name has not been entered
5.4.0 – Released October 11, 2024
Improvements:
- Camera-related alarms and alarm indicators now match their location on the machine
5.3.0 – Released September 4, 2024
Fixes:
- Increased applicator coil minimum detection current to reduce probability of configuration errors
Improvements:
- “plant” changed to “center” in distance caption
- Improved text alignment in some widgets
New Features:
- Added toolbar layout diagram for 3+3+3 module configuration
- Added factory reset button on service page
- Reset camera to blade distance to default when set to zero
5.2.8 – Released July 12, 2024
Fixes:
- Fixed an issue with 3-line backbones having incorrect timing on the center actuator
5.2.7 – Released June 25, 2024
Fixes:
- Fixed an issue with update 5.2.6 that prevented some actuators from firing on machines with less than 3 backbones.
5.2.6 – Released June 21, 2024
Fixes:
- Fixed an issue with update 5.2.5 that prevented some actuators from firing on machines with 4 or more backbones
5.2.5 – Released June 19, 2024
Fixes:
- Fixed an issue where the center actuator would not close in some uncommon machine configurations
5.2.4 – Released June 14, 2024
Improvements:
- Flush all applicator nozzles at the same time
- Hide the dispense length factor internal setting for VRF
Fixes:
- Alignment of dispensed liquid is now correct for 3-line modules
- Updated security for factory calibration
5.2.3 – Released May 20, 2024
Improvements:
- Better prediction of applicator flow rate
- Allow applicator pressure to be set up to 8 bar
- Show warning message on applicator page if no valves connected
- Limit response times to positive numbers to prevent accidentally making it negative during factory calibration
Fixes:
- Applicator flow rate calculation can no longer result in a negative flow rate
- Applied rate data per plant is now being broadcast for 100% of plants that were applied to
5.2.2 – Released May 17, 2024
Fixes:
- Left bed actuator connection order for SC280
5.2.1 – Released April 30, 2024
Fixes:
- Side shift locked message is no longer cut off in Spanish language Improvements:
Improvements:
- Better visibility of “side shift locked message”
5.2.0 – Released April 17, 2024
New features:
- Spanish language option
- Side shift position is locked/held after manual shift, until it is released by pressing the lock/unlock button
- SRF UI is enabled if all the manifold sensors are present and valid, even if no solenoids are plugged in
- Cellular signal level displayed at top right of navigation bar
- Added general diagnostics page
- Animated display of module lift over the buttons when they are disabled
- Sliding bar to show side shift position
Fixes:
- Language selection persists through restarting the machine
- Translation applies to the safety disclaimer page
- Side shift calibration is reversed for 4-40 chassis left bed
- Fixed SRF histogram percentile calculation which was off by 1 bin
- Side shift now does not engage until height control is engaged
- Plant type selector is now visible on the setup page again
5.1.0 – Released December 12, 2023
Fixes:
- Fixed an issue where timeout occurs too early during applicator flow calibration
New features:
- Color-coded key for variable rate prescription histogram
- Automatically set the pressure setpoint to the current pump pressure when zeroing the flow sensor
- Allow pressure setpoint to be entered manually if needed
- Allow decimal point in variable rate dose when using metric units
- Show the plants counter when variable rate is installed
5.0.3
Fixes:
- Show 0 on the applied rate graph above 100-percentile
- Fixed visible alignment of prescription graph
5.0.2
Fixes:
- Fixed an issue where position the applicator valve opens is not calculated correctly if the previous plant on that line had a different prescription
5.0.1
Re-release of 5.0.0 to fix a deployment issue.
5.0.0
New features:
- Added support for variable rate fertilizer add-on
- Speed-adaptive actuation offset
- Replace commodity readout with machine speed on sidebar
- Improved alarm messages to differentiate module lift and height control
Fixes:
- Only allow tilt in run mode
- Removed commodity selector since commodity detection is automatic
4.10.2
Fixes:
- Disabled wheel pressure sensor alarm and functionality
- Alignment of background on control page
4.10.1
Fixes:
- Features and fixes that were intended for 4.10.0 are in this release.
4.10.0
New features:
- Show acres on plants counter
Fixes:
- Don’t reset the plants counter on startup
4.9.0
New features:
- Manifold Flush functionality added to toolbar service page. This is for use with the low pressure oil filtration pump.
4.8.0
New features:
- Speed readout on toolbar service page
Fixes:
- Limit blade speed to max of 100%
- Set default home positions for outer beds when initializing a new SC440 chassis
4.7.2
Fixes:
- Disable side shift control buttons when machine is in stop state
- Add a 3 second delay on setting heartbeat alarm on HMI
4.7.1
Fixes:
- Don’t allow blade speed to be a negative number
4.7.0
Fixes:
- Reset plants counter on startup
4.6.0
New features:
- Settable home position for left and right beds
Fixes:
- Disable module lift coil outputs for inactive lanes
- Use larger integer type for side shift position to prevent overflow on side shifts with more than 6 inches of travel